Rooftop teargas filtration system (RTS)
Ref no. RTS
The modular CBRN system supplies clean filtered air and creates overpressure inside the vehicle to maintain a clean environment at 200-400Pa inside the vehicle. This system is designed for Teargas and CBRN filter use.
The CBRN system is a bolt-on assembly and requires four holes with bushes:
1. Electrical Interface
2. Air Inlet
3. Manual switchover interface
4. Overpressure Relief Valve Interface
The system is mounted via 4x M16 bolts onto bushes supplied by the client.
The CBRN system has an integrated 3-way valve system allowing the user to switch between CBRN filtration and Dust filtration by means of adjusting three-way way valve manually with the provided handle.
THE CBRN System is fitted with an AEP 54 Edition 2 Cas Compliant Filter available from all leading filter suppliers and includes Dragger, EMCEL, and MDH Defence.
The Human Machine Interface (HMI) is simple yet effective in displaying all required checks to ensure CBRN threat protection. This includes filter not installed, CBRN mode active, CBRN filter blocked, Prefilter blocked and overpressure warning. An audible alarm warns the operator if CRBN protection is not active when the system is switched on. The life of the filter is monitored by a resettable hour counter.
Specifications
Reference No: RTS-170 |
|
CBRN Protection | AEP54 Edition 2 (Oct 2014) Gas Test Compliant; STANAG 4632 (AEP-54) |
Airflow | 170m3/h |
Overpressure | Pressure Regulation between 200-500Pa |
CBRN Filter Cartridge | Ø 325mm x 369mm H AEP54 Edition 2 (Oct 2014) Gas Test Compliant |
Filtration | 95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with CBRN Filtration Cartridge |
HMI | Stand Alone LED fault and/or warning indication & alarm |
Fault Finding | Bluetooth |
Enclosure Protection | IP54 |
System Weight | 150kg excluding armour protection |
Power Supply | 28VDC, 30A |
OPTIONAL | |
Automatic 3Way Valve Switching | Automatic 3 way valve switching when activating the CBRN system from the default Fresh Air Filtration to CBRN filtration |
Network | CAN Bus for integration to vehicle diagnostics |
Armour Protection |